Metzenbaum Scissors STR, TC, 145mm
Description
The Metzenbaum Scissors STR, TC, 145mm are premium surgical scissors specifically designed for delicate tissue dissection and cutting in general surgery and various specialized procedures. Known for their precision and reliability, these scissors are a fundamental tool in operating rooms, surgical kits, and clinical environments where fine tissue handling is essential.
Featuring a straight blade design, the Metzenbaum Scissors are ideal for clean, controlled cuts along linear paths, making them especially useful for dissecting soft tissues, trimming internal structures, or cutting sutures in confined or straight-lined anatomical regions. Unlike standard surgical scissors, Metzenbaum scissors have a longer shank-to-blade ratio, providing better reach and accuracy in deeper surgical fields while minimizing trauma to surrounding tissue.
The cutting edges are reinforced with Tungsten Carbide (TC) inserts, offering exceptional hardness, sharpness, and wear resistance. Tungsten Carbide is far superior to regular stainless steel in maintaining a razor-sharp edge, enabling smooth, consistent cutting performance over extended periods of use. The TC blades reduce the need for frequent sharpening and ensure clean, precise cuts with minimal tissue damage, even after repeated sterilization.
At 145mm in length, the scissors provide balanced reach and control, suitable for both shallow and moderately deep surgical areas. The slim, tapered design improves visibility and access during delicate dissection, particularly in areas where space is limited.
Manufactured from high-quality surgical-grade stainless steel, these scissors are corrosion-resistant, biocompatible, and fully autoclavable, ensuring safety and durability in sterile environments. The robust construction combined with the ergonomic handle design provides a secure grip, enhancing surgeon comfort and minimizing hand fatigue during long procedures.
Features:
Made of medical-grade German stainless steel.
Passivation procedure performed to prevent rust and improve corrosion resistance.
Non-sterile, reusable and autoclavable.
Form test, boiling test and performance test carried out.
Lifetime warranty against defects in materials and workmanship.
PRODUCT CARE
Surgical Instrument Cleaning Guide: Best Practices for Healthcare Facilities
Maintaining properly cleaned and sterilized surgical instruments is essential for patient safety and infection prevention. A well-structured reprocessing system helps healthcare facilities minimize contamination risks, improve clinical outcomes, and ensure instruments remain safe and effective for repeated use.
Below is a step-by-step guide to effective surgical instrument cleaning and sterilization.
Immediate Cleaning After Use
The cleaning process should begin immediately after a medical procedure. Delays may allow blood, tissue, and bodily fluids to dry onto instruments, making debris harder to remove and increasing the possibility of biofilm formation.
At the point of use, staff should gently wipe instruments with a sterile damp cloth or sponge. Moisture-retaining products such as enzymatic sprays, gels, or foams may be applied to prevent organic material from drying before detailed cleaning begins.
For heavily contaminated devices, soaking in an enzymatic cleaning solution can help loosen stubborn biological residue and simplify the cleaning process.
Safe Handling and Transportation
Used instruments should be transferred safely from procedure rooms to the reprocessing area using sealed, puncture-resistant containers designed to prevent leakage and accidental exposure.
Containers should be clearly identified as biohazardous to reduce contamination risks and ensure safe handling by healthcare personnel.
Thorough Manual Cleaning
Manual cleaning plays a key role in eliminating visible contamination before advanced processing methods are used.
Healthcare staff should clean instruments using soft cleaning brushes, approved detergents, and lint-free cloths. Special attention must be given to difficult-to-clean areas such as hinges, grooves, lumens, locking mechanisms, and joints where debris can accumulate.
After scrubbing, instruments should be rinsed thoroughly with purified water, such as distilled or deionized water, to remove detergent residue.
Advanced Mechanical Cleaning
Mechanical cleaning systems provide an additional level of decontamination by removing microscopic particles that manual cleaning may miss.
Equipment such as ultrasonic cleaners and automated washer-disinfectors use sound vibrations and programmed wash cycles to improve cleaning effectiveness.
To achieve proper results, instruments must be arranged correctly within the equipment to ensure complete exposure during cleaning. Staff should always follow the manufacturer’s usage instructions and routinely inspect equipment to maintain performance standards.
Effective Sterilization Methods
Sterilization is a crucial phase in the instrument reprocessing cycle because it destroys harmful microorganisms, including bacteria, spores, and other infectious contaminants.
Several sterilization options are commonly used in healthcare settings, including:
- Steam sterilization
- Gas-based sterilization using ethylene oxide
- Hydrogen peroxide plasma sterilization
- Dry heat sterilization
The most suitable method should be selected according to the type of instrument and the manufacturer’s recommended guidelines.
Residue Removal Following Sterilization
When gas sterilization methods are used, instruments should be carefully rinsed afterward with purified water to eliminate any chemical residue that could potentially affect patient safety.
Proper post-processing ensures instruments are safe for clinical use.
Proper Drying Procedures
Instruments exposed to steam or gas sterilization should be allowed sufficient time to cool or aerate before drying begins.
Complete drying is essential to preserve instrument quality and prevent moisture-related damage such as rust, corrosion, or staining. Lint-free cloths or compressed air may be used to remove remaining moisture effectively.
Instrument Lubrication
Surgical tools with hinges, joints, or movable parts require periodic lubrication to maintain smooth functionality and reduce wear over time.
Only medical-grade, water-soluble lubricants should be used, and application should always follow manufacturer recommendations to avoid buildup or damage.
Inspection and Functional Assessment
Every instrument should undergo a careful inspection before packaging and storage.
Healthcare staff should evaluate:
- Overall cleanliness
- Structural condition
- Operational performance
- Signs of wear, cracks, chips, or damage
Magnification tools may help detect defects that are not visible to the naked eye. Instruments that fail inspection should be removed and reprocessed or repaired.
Sterile Packaging Requirements
Correct packaging helps preserve sterility until instruments are needed for patient care.
Depending on the device type, facilities may use sterilization pouches, wraps, or rigid containment systems. Packages should be securely sealed to reduce contamination risks and labeled with important details such as sterilization date, contents, and tracking information.
Storage and Shelf Management
Sterile instruments should be stored in a clean, dry, and controlled environment to preserve their integrity.
Proper storage practices include:
- Keeping instruments off the floor
- Avoiding excessive moisture or direct sunlight
- Maintaining controlled room conditions
- Organizing inventory using a first-in, first-out system
This approach helps ensure older sterilized products are used before newly processed items.
Documentation and Quality Compliance
Accurate recordkeeping is an important part of surgical instrument reprocessing and regulatory compliance.
Healthcare facilities should maintain detailed documentation that includes:
- Sterilization dates and cycle information
- Processing methods used
- Equipment performance records
- Staff/operator details
- Biological monitoring and testing results
- Maintenance and validation logs
Organized documentation improves traceability, supports audits, and helps facilities meet healthcare quality standards.
Final Thoughts
A consistent and properly managed cleaning process is essential to maintaining surgical instrument performance and protecting patient safety. From point-of-use cleaning to storage and documentation, every stage contributes to infection control, regulatory compliance, and better healthcare outcomes.
Notified by email when this product becomes available
Have a question?
Recommendations
Recently viewed
Precision Black Series
Catalog
The Precision Black Series is a premium line of dental instruments engineered for professionals who demand comfort, performance, and style. Featuring lightweight, hollow black titanium nitride–coated handles, these tools deliver superior ergonomics and reduced operator fatigue. The distinctive matte black finish minimizes glare, while plasma-coated titanium nitride gold tips ensure exceptional durability, corrosion resistance, and lasting sharpness. Designed to enhance control and accuracy, the Precision Black Series redefines the standard of modern dental instrumentation.